Advertisement
If you have a new account but are having problems posting or verifying your account, please email us on hello@boards.ie for help. Thanks :)
Hello all! Please ensure that you are posting a new thread or question in the appropriate forum. The Feedback forum is overwhelmed with questions that are having to be moved elsewhere. If you need help to verify your account contact hello@boards.ie

Burris scope help!

Options
  • 15-10-2017 8:31pm
    #1
    Registered Users Posts: 121 ✭✭


    Hi I have a burris fourx 3x12x56 I was just wondering would anyone know is it possible once the rifle is zeroed my windage dial when zeroed to rifle is 9.1 I have seen on other scopes you can loosen a screw an set the dial to 0 while still being zeroed and I was wondering would anyone know if it is possible to do it on this scope as their low profile dials, also how to change the battery on it as in the box it came with 2 spare battery's but I cannot seem to find where is goes I have checked on Google ect but theirs limited information unfortunately.
    Cheers
    Picture attached


Comments

  • Registered Users Posts: 877 ✭✭✭Wadi14


    https://www.youtube.com/watch?v=7nu97JpPYLg
    https://www.youtube.com/watch?v=ZamdB2yxyhg

    have a look at these, they may help you in resetting to zero and changing the battery, they may not be identical to your scope but most scopes operate similarly


  • Registered Users Posts: 2,333 ✭✭✭J.R.


    BURRIS MANUAL

    battery replacement explained

    http://www.burrisoptics.com/sites/default/files/content/products/manuals/cqb1-4xuserguide.pdf

    http://stevespages.com/pdf/burris_riflescope.pdf


    Replace battery - " the battery is placed on the lefthand side, same as the light adjustment. Turn the adjustment forward until it stops, on the outside on the illumination adjustment there is a cap that can be a little tricky to loosen. It has a bit rough edges to make it easier to grip, turn it forward and under it you´ll find the battery."


  • Registered Users Posts: 2,333 ✭✭✭J.R.


    http://www.burrisoptics.com/sites/default/files/content/products/manuals/cqb1-4xuserguide.pdf page 3

    Adjust dial to zero

    The windage and elevation knobs on
    Burris 1-4x models are designed for
    precise adjustment.The knobs are
    calibrated so that 1 click = .5 MOA.
    Both dials can be reset to“0”once the
    scope is sighted-in.Once you have
    successfully zeroed your scope, you
    can set the zero on your dials with
    these simple steps:

    1.With turret caps removed, grip or
    press down on knob top firmly and
    keep knob from turning.
    2. Put pen or other small object into
    the small hole located on the dial,
    180º from“0”.

    3. Keeping firm grip or pressure on the
    knob, use the pen to turn the dial
    back to zero, lining up the number
    zero with the white indicator dot.
    Only the numbered dial should
    move – do not allow the entire knob
    to move or else you will alter your
    windage and elevation zero settings


Advertisement