Hi all,
Vanilla are planning an update to the site on April 24th (next Wednesday). It is a major PHP8 update which is expected to boost performance across the site. The site will be down from 7pm and it is expected to take about an hour to complete. We appreciate your patience during the update.
Thanks all.

12v Output from HKC Panel for Home Automation

Options
  • 18-10-2016 8:52pm
    #1
    Registered Users Posts: 466 ✭✭


    Hi lads,

    I have a smart home server that I am looking to alert me when the alarm is activated.

    I already used a zone for arm/disarm so I have that on my smart home app but now I want to be able to have the alarm panel tell the smart home panel when it is going off.

    I have tried changing output 2 to alarm+and internal bell+ but neither work. I am looking for a 12v output. I thought one of the above would give me that but it didn't work.

    Any ideas?


Comments

  • Moderators, Home & Garden Moderators, Technology & Internet Moderators Posts: 24,789 Mod ✭✭✭✭KoolKid


    Take a permanent 12 v + from the aux power & take the negative from the output & programme as alarm -
    That pair will generate 12vdc when an alarm activates.


  • Registered Users Posts: 466 ✭✭17larsson


    Thanks for that KoolKid.
    The smart home server's input needs a 12v+ signal so not a circuit as such if that makes sense. Is there anyway of creating that do you know?


  • Moderators, Home & Garden Moderators, Technology & Internet Moderators Posts: 10,952 Mod ✭✭✭✭Stoner


    17larsson wrote:
    Thanks for that KoolKid. The smart home server's input needs a 12v+ signal so not a circuit as such if that makes sense. Is there anyway of creating that do you know?
    I think that's what he gave you.

    Under what conditions do you want the 12V

    Alarm activation ?


  • Registered Users Posts: 466 ✭✭17larsson


    Yes but with that way the 12v+ is constant and the negative comes on at alarm activation to complete the circuit.
    My input is just a single connection that needs a 12v+ signal to activate.
    I tried setting the output to 'alarm +' but it doesn't work either.
    I'm definitely missing something basic here but I can't get it


  • Registered Users Posts: 9,605 ✭✭✭gctest50


    Stick an isolator between the two - it'd be a good idea anyway


  • Advertisement
  • Registered Users Posts: 466 ✭✭17larsson


    I could use a 12v conactor and break the 12v signal through it but I just thought there would be a way of doing it with just the panel


  • Moderators, Home & Garden Moderators, Technology & Internet Moderators Posts: 24,789 Mod ✭✭✭✭KoolKid


    Probably not enough power from the output.
    Use negative output to trigger 1 12vdc relay with the aux positive going through the N O contacts.


  • Registered Users Posts: 466 ✭✭17larsson


    KoolKid wrote: »
    Probably not enough power from the output.
    Use negative output to trigger 1 12vdc relay with the aux positive going through the N O contacts.
    Yeah that's what I'll have to do, cheer for the replies all